Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37.089
Filtrar
1.
Rapid Commun Mass Spectrom ; 38(12): e9739, 2024 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-38605205

RESUMO

RATIONALE: 4,7-Dichloroquinoline (DCQ) represents a group of synthetic molecules inspired by natural products with important roles in biological and biomedical areas. This work aimed to characterize DCQ and its derivatives by high-resolution electrospray ionization (ESI) mass spectrometry and tandem mass spectrometry (ESI-MS/MS), supported by theoretical calculations. Biological assays were carried out with DCQ and its derivatives to determine LC50 values against Aedes aegypti larvae. METHODS: Five DCQ derivatives were synthesized by using previously described protocols. ESI-MS/MS analyses were carried out with a quadrupole/time-of-flight and ion-trap instrument. The proposed gas-phase protonation sites and fragmentation were supported by density functional theory calculations. The larvicidal tests were performed with the Ae. aegypti Rockefeller strain, and the LC50 values were determined by employing five test concentrations. Larval mortality was determined after treatment for 48 h. RESULTS: DCQ bromides or aldehydes (C-3 or C-8 positions), as well as the trimethylsilyl derivative (C-3 position), were prepared. Detailed ESI-MS/MS data revealed heteroatom elimination through an exception to the even-electron rule, to originate open-shell species. Computational studies were used to define the protonation sites and fragmentation pathways. High activity of DCQ and its derivatives against Ae. aegypti larvae was demonstrated. CONCLUSION: Our results provided a well-founded characterization of the fragmentation reactions of DCQ and its derivatives, which can be useful for complementary studies of the development of a larvicidal product against Ae. aegypti.


Assuntos
Aedes , Espectrometria de Massas por Ionização por Electrospray , Animais , Espectrometria de Massas por Ionização por Electrospray/métodos , Espectrometria de Massas em Tandem/métodos , Larva
2.
J Mass Spectrom ; 59(5): e5025, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38607249

RESUMO

Energy-resolved mass spectrometry (ERMS) and an isotopically labelled internal standard were successfully combined to accurately quantify a tryptic peptide despite the presence of an isobaric interference. For this purpose, electrospray ionisation tandem mass spectrometry (ESI-MS/MS) experiments were conducted into an ion trap instrument using an unconventional 8 m/z broadband isolation window, which encompassed both the tryptic peptide and its internal standard. Interference removal was assessed by determining an excitation voltage that was high enough to maintain a constant value for the analyte/internal standard peaks intensity ratio, thus ensuring accurate quantification even in the presence of isobaric contamination. Pseudo-multiple reaction monitoring (MRM) was employed above this excitation voltage to quantify the trypic peptide. The internal standard calibration model showed no lack of fit and exhibited a linear dynamic range from 0.5 µM up to 2.5 µM. The detection limit was 0.08 µM. The accuracy of the method was evaluated by quantifying the tryptic peptide of three reference samples intentionally contaminated with the isobaric interference. All the reference samples were accurately quantified with ∼1% deviation despite the isobaric contamination. Furthermore, we have demonstrated that this methodology can also be applied to quantify the isobaric peptide by standard additions down to 0.2 µM. Finally, liquid chromatography ERMS (LC ERMS) experiments yielded similar results, suggesting the potential of the proposed methodology for analysing complex samples.


Assuntos
60705 , Espectrometria de Massas em Tandem , Espectrometria de Massas por Ionização por Electrospray , Isótopos , Peptídeos
3.
Zhongguo Zhong Yao Za Zhi ; 49(4): 932-941, 2024 Feb.
Artigo em Chinês | MEDLINE | ID: mdl-38621900

RESUMO

This study explored the biosynthesis of bufadienolides(BDs) in Bufo bufo gargarizans to solve the dilemma of the decreasing resources of B. bufo gargarizans and provide a theoretical basis for the sustainable utilization of the resources. Ultra-high performance liquid chromatography-Orbitrap-mass spectrometry(UHPLC-Orbitrap-MS) was employed to detect the synthesis sites of BDs in B. bufo gargarizans, and the results were verified by desorption electrospray ionization-mass spectrometry imaging(DESI-MSI) and homogenate incubation experiments. BDs in B. bufo gargarizans had the highest content in the liver and the highest concentration in the gallbladder, in addition to the parotid gland and skin, which suggested that the liver could synthesize BDs. The results of DESI-MSI also showed that BDs were mainly enriched in the liver rather than the immature parotid gland. The incubation experiment of liver homogenates demonstrated the liver of B. bufo gargarizans had the ability to synthesize BDs. This study showed that the liver was a major organ for the synthesis of BDs in B. bufo gargarizans during metamorphosis, development, and growth, which provided strong theoretical support for the biosynthesis of BDs and the sustainable utilization of B. bufo gargarizans resources.


Assuntos
Bufanolídeos , Animais , Bufo bufo , Distribuição Tecidual , Bufonidae , Espectrometria de Massas por Ionização por Electrospray
4.
Sci Rep ; 14(1): 7770, 2024 04 02.
Artigo em Inglês | MEDLINE | ID: mdl-38565919

RESUMO

Neolitsea pallens (D. Don) Momiyama & H. Hara (Family: Lauraceae), commonly known as Pale Litsea, is an evergreen small tree, distributed in India at altitudes of 1500-3000 m. Traditionally utilized for various purposes, its leaves and bark are used as spices, and the plant is valued in preparing a hair tonic from freshly pressed juice. Secondary metabolites of the leaves have not comprehensively been analysed so far. The objective of the study was to determine the chemical composition of the leaves by analysing their 25% aqueous methanol extract with the aid of ultra-performance liquid chromatography quadrupole time of flight tandem mass spectrometry. Overall, 56 compounds were identified in the study. Phenolics represented by phenolic acids, phenolic glycosides, proanthocyanidins, and flavonoids were the main components of the extract.


Assuntos
Lauraceae , Espectrometria de Massas em Tandem , Espectrometria de Massas por Ionização por Electrospray/métodos , Cromatografia Líquida de Alta Pressão/métodos , Extratos Vegetais/química , Fenóis/análise , Folhas de Planta/química , Compostos Fitoquímicos/análise
5.
Rapid Commun Mass Spectrom ; 38(11): e9745, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38591150

RESUMO

RATIONALE: As per International Council for Harmonization (ICH) drug stability test guideline Q1A(R2), inherent stability characteristics of a drug should be studied. This work was designed to investigate inherent degradation characteristics of the drug idelalisib under ICH prescribed stress conditions, identify its degradation products, and postulate their corresponding degradation pathways. METHODS: Idelalisib was subjected to the ICH prescribed conditions of hydrolytic (neutral, acidic, and alkaline), photolytic, oxidative, and thermal stress according to ICH guideline Q1A(R2). An ultrahigh-performance liquid chromatography with photodiode array (UHPLC-PDA) method was developed to adequately resolve the drug from its degradation products, validated as per the ICH guidelines, and subsequently extended to UHPLC with electrospray ionization quadrupole time-of-flight mass spectrometry (ESI-QTOFMS) studies to identify the degradation products. RESULTS: Significant degradation was noted under conditions of acidic/alkaline hydrolysis, acid photolysis, and oxidative stress. The UHPLC/ESI-QTOFMS studies revealed the generation of four degradation products (I-IV), which were satisfactorily resolved from the drug by UHPLC on a Kinetex® C18 (100 × 4.6 mm; 2.6 µm) column by the developed isocratic elution method. Detection wavelength was selected as 270 nm. All the degradation products (I-IV) could be identified and characterized from their mass spectral data. The degradation pathways for the generation of various products from the drug were postulated. CONCLUSIONS: A UHPLC-PDA method was developed and validated for idelalisib. Four degradation products of idelalisib were revealed through UHPLC/ESI-QTOFMS studies, and corresponding degradation pathways were postulated for the same.


Assuntos
Purinas , Quinazolinonas , Espectrometria de Massas por Ionização por Electrospray , Espectrometria de Massas em Tandem , Espectrometria de Massas por Ionização por Electrospray/métodos , Espectrometria de Massas em Tandem/métodos , Cromatografia Líquida/métodos , Hidrólise , Estabilidade de Medicamentos , Oxirredução , Fotólise , Cromatografia Líquida de Alta Pressão/métodos
6.
Biomed Microdevices ; 26(2): 22, 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38592604

RESUMO

We report a centrifugal microfluidic device that automatically performs sample preparation under steady-state rotation for clinical applications using mass spectrometry. The autonomous microfluidic device was designed for the control of liquid operation on centrifugal hydrokinetics (CLOCK) paradigm. The reported device was highly stable, with less than 7% variation with respect to the time of each unit operation (sample extraction, mixing, and supernatant extraction) in the preparation process. An agitation mechanism with bubbling was used to mix the sample and organic solvent in this device. We confirmed that the device effectively removed the protein aggregates from the sample, and the performance was comparable to those of conventional manual sample preparation procedures that use high-speed centrifugation. In addition, probe electrospray ionization mass spectrometry (PESI-MS) was performed to compare the device-treated and manually treated samples. The obtained PESI-MS spectra were analyzed by partial least squares discriminant analysis, and the preparation capability of the device was found to be equivalent to that of the conventional method.


Assuntos
Microfluídica , Espectrometria de Massas por Ionização por Electrospray , Centrifugação , Dispositivos Lab-On-A-Chip , Rotação
7.
Anal Chem ; 96(15): 5746-5751, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38556995

RESUMO

Microflow porous graphitized carbon liquid chromatography (PGC-LC) combined with negative mode ionization mass spectrometry (MS) provides high resolution separation and identification of reduced native N-glycan structural isomers. However, insufficient spray quality and low ionization efficiency of N-glycans present challenges for negative mode electrospray. Here, we evaluated the performance of a recently developed multinozzle electrospray source (MnESI) and accompanying M3 emitter for microflow PGC-LC-MS analysis of N-glycans in negative mode. In comparison to a standard electrospray ionization source, the MnESI with an M3 emitter improves signal intensity, identification, quantification, and resolution of structural isomers to accommodate low-input samples.


Assuntos
Carbono , 60705 , Carbono/química , Espectrometria de Massas em Tandem/métodos , Porosidade , Polissacarídeos/química , Espectrometria de Massas por Ionização por Electrospray/métodos
8.
Anal Chem ; 96(14): 5589-5597, 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38556723

RESUMO

Sebum lipids are composed of nonpolar lipids, and they pose challenges for mass spectrometry-based analysis due to low ionization efficiency and the existence of numerous isomers and isobars. To address these challenges, we have developed ethyl 2-oxo-2-(pyridine-3-yacetate as a charge-tagging Paternò-Büchi reagent and Michler's ketone as a highly efficient photocatalyst, achieving ∼90% conversion for C═C derivatization under 440 nm LED irradiation. This derivatization, when coupled with electrospray ionization-tandem mass spectrometry, boosts the detection of sebum lipids and pinpoints C═C location in a chain-specific fashion. Identification and quantitation of isomers are readily achieved for wax esters, a class of underexplored sebum lipids, which have C═C bonds distributed in fatty alcohol and fatty acyl chains. A shotgun analysis workflow has been developed by pairing the offline PB derivatization with cyclic ion mobility spectrometry-mass spectrometry. Besides the dominant n-10 C═C location in unsaturated wax esters, profiling of low abundance isomers, including the rarely reported n-7 and n-13 locations, is greatly enhanced due to separations of C═C diagnostic ions by ion mobility. Over 900 distinct lipid structures from human sebum lipid extract have been profiled at the chain-specific C═C level, including wax esters (500), glycerolipids (393), and cholesterol esters (22), far more exceeding previous reports. Overall, we have developed a fast and comprehensive lipidomic profiling tool for sebum samples, a type of noninvasive biofluids holding potential for the discovery of disease markers in distal organs.


Assuntos
Lipídeos , Sebo , Humanos , Lipídeos/análise , Sebo/química , Espectrometria de Mobilidade Iônica , Lipidômica , Espectrometria de Massas por Ionização por Electrospray/métodos , Íons
9.
Anal Biochem ; 689: 115497, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38461948

RESUMO

The naturally occurring peptides and digested proteins of fetal versus adult bovine serum were compared by LC-ESI-MS/MS after correction against noise from blank injections and random MS/MS spectra as statistical controls. Serum peptides were extracted by differential precipitation with mixtures of acetonitrile and water. Serum proteins were separated by partition chromatography over quaternary amine resin followed by tryptic digestion. The rigorous X!TANDEM goodness of fit algorithm that has a low error rate as demonstrated by low FDR q-values (q ≤ 0.01) showed qualitative and quantitative agreement with the SEQUEST cross correlation algorithm on 12,052 protein gene symbols. Tryptic digestion provided a quantitative identification of the serum proteins where observation frequency reflected known high abundance. In contrast, the naturally occurring peptides reflected the cleavage of common serum proteins such as C4A, C3, FGB, HPX, A2M but also proteins in lower concentration such as F13A1, IK, collagens and protocadherins. Proteins associated with cellular growth and development such as actins (ACT), ribosomal proteins like Ribosomal protein S6 (RPS6), synthetic enzymes and extracellular matrix factors were enriched in fetal calf serum. In contrast to the large literature from cord blood, IgG light chains were absent from fetal serum as observed by LC-ESI-MS/MS and confirmed by ELISA.


Assuntos
Espectrometria de Massas por Ionização por Electrospray , Espectrometria de Massas em Tandem , Espectrometria de Massas em Tandem/métodos , Espectrometria de Massas por Ionização por Electrospray/métodos , Peptídeos/química , Proteínas Sanguíneas/análise , Digestão
10.
J Am Soc Mass Spectrom ; 35(4): 683-695, 2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38518248

RESUMO

The human cerebellum is an ultraspecialized region of the brain responsible for cognitive functions and movement coordination. The fine mechanisms through which the process of aging impacts such functions are not well understood; therefore, a rigorous exploration of this brain region at the molecular level is deemed necessary. Gangliosides, sialylated glycosphingolipids, highly and specifically expressed in the human central nervous system, represent possible molecular markers of cerebellum development and aging. In this context, for a comprehensive determination of development- and age-specific components, we have conducted here a comparative profiling and structural determination of the gangliosides expressed in fetal cerebellum in two intrauterine developmental stages and aged cerebellum by ion mobility separation (IMS) mass spectrometry (MS) and tandem MS (MS/MS). Due to the high sensitivity and efficiency of separation provided by IMS MS, no less than 551 chemically distinct species were identified, which represents 4.5 times more gangliosides than ever discovered in this brain region. The detailed assessment of fetal vs aged cerebellum gangliosidome showed marked discrepancies not only in the general number of the species expressed, but also in their sialylation patterns, the modifications of the glycan core, and the composition of the ceramides. All of these characteristics are potential markers of cerebellum development and aging. The structural analysis by collision-induced dissociation (CID) documented the occurrence of GD1b (d18:1/18:0) isomer in the fetal cerebellum in the second gestational trimester, with all probability of GQ1b (t18:1/18:0) in the near-term fetus and of GQ1b (d18:1/18:0) in aged cerebellum.


Assuntos
Espectrometria de Massas por Ionização por Electrospray , Espectrometria de Massas em Tandem , Humanos , Idoso , Espectrometria de Massas por Ionização por Electrospray/métodos , Gangliosídeos/análise , Encéfalo , Cerebelo
11.
Anal Chem ; 96(14): 5478-5488, 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38529642

RESUMO

PubChem serves as a comprehensive repository, housing over 100 million unique chemical structures representing the breadth of our chemical knowledge across numerous fields including metabolism, pharmaceuticals, toxicology, cosmetics, agriculture, and many more. Rapid identification of these small molecules increasingly relies on electrospray ionization (ESI) paired with tandem mass spectrometry (MS/MS), particularly by comparison to genuine standard MS/MS data sets. Despite its widespread application, achieving consistency in MS/MS data across various analytical platforms remains an unaddressed concern. This study evaluated MS/MS data derived from one hundred molecular standards utilizing instruments from five manufacturers, inclusive of quadrupole time-of-flight (QTOF) and quadrupole orbitrap "exactive" (QE) mass spectrometers by Agilent (QTOF), Bruker (QTOF), SCIEX (QTOF), Waters (QTOF), and Thermo QE. We assessed fragment ion variations at multiple collisional energies (0, 10, 20, and 40 eV) using the cosine scoring algorithm for comparisons and the number of fragments observed. A parallel visual analysis of the MS/MS spectra across instruments was conducted, consistent with a standard procedure that is used to circumvent the still prevalent issue of mischaracterizations as shown for dimethyl sphingosine and C20 sphingosine. Our analysis revealed a notable consistency in MS/MS data and identifications, with fragment ions' m/z values exhibiting the highest concordance between instrument platforms at 20 eV, the other collisional energies (0, 10, and 40 eV) were significantly lower. While moving toward a standardized ESI MS/MS protocol is required for dependable molecular characterization, our results also underscore the continued importance of corroborating MS/MS data against standards to ensure accurate identifications. Our findings suggest that ESI MS/MS manufacturers, akin to the established norms for gas chromatography mass spectrometry instruments, should standardize the collision energy at 20 eV across different instrument platforms.


Assuntos
Esfingosina , Espectrometria de Massas em Tandem , Espectrometria de Massas em Tandem/métodos , Espectrometria de Massas por Ionização por Electrospray/métodos , Cromatografia Gasosa-Espectrometria de Massas , Íons
12.
Artigo em Inglês | MEDLINE | ID: mdl-38513430

RESUMO

Developing a knob-into-hole asymmetric bispecific IgG1 monoclonal antibody (mAb) poses manufacturing challenges due to the expression of chain pairing variants, also called mispaired species, in the desired product. The incorrect pairing of light and heavy chains could result in heterogeneous mispaired species of homodimers, heterodimers, light chain swapping, and low molecular weight species (LMWS). Standard chromatography, capillary electrophoretic, or spectroscopic methods poorly resolve these from the main variants. Here, we report a highly sensitive reverse-phase polyphenyl ultra-high-performance liquid chromatography (RP-UHPLC) method to accurately measure mispaired species of Duet mAb format, an asymmetric IgG1 bispecific mAb, for both process development and quality control analytical tests. Coupled with electrospray ionization mass spectrometry (ESI-MS), it enabled direct online characterization of mispaired species. This single direct assay detected diverse mispaired IgG-like species and LMWS. The method resolved eight disulfide bonds dissociated LMWS and three mispaired LMWS. It also resolved three different types of IgG-like mispaired species, including two homodimers and one heterodimer. The characterization and quantification simultaneously enabled the cell line selection that produces a lesser heterogeneity and lower levels of mispaired species with the desired correctly paired product. The biological activity assessment of samples with increased levels of these species quantified by the method exhibited a linear decline in potency with increasing levels of mispaired species in the desired product. We also demonstrated the utility of the technique for testing in-process intermediate materials to determine and assess downstream purification process capability in removing diverse mispaired IgG-like species and LMWS to a certain level during the downstream purification process. Our investigation demonstrates that adopting this method was vital in developing asymmetric bispecific mAb from the initial stage of cell line development to manufacturing process development. Therefore, this tool could be used in the control strategy to monitor and control mispaired species during manufacturing, thus improving the quality control of the final product.


Assuntos
Anticorpos Biespecíficos , Espectrometria de Massas por Ionização por Electrospray , Imunoglobulina G/química , Cromatografia de Fase Reversa , Domínios Proteicos , Anticorpos Biespecíficos/química , Anticorpos Monoclonais/química
13.
Anal Chem ; 96(10): 4146-4153, 2024 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-38427846

RESUMO

Unraveling the mechanism by which native proteins are charged through electrospray ionization (ESI) has been the focus of considerable research because observable charge states can be correlated to biophysical characteristics, such as protein folding and, thus, solution conformation. Difficulties in characterizing electrosprayed droplets have catalyzed the use of molecular dynamics (MD) to provide insights into the mechanisms by which proteins are charged and transferred to the gas phase. However, prior MD studies have utilized metal ions, primarily Na+, as charge carriers, even though proteins are primarily detected as protonated ions in the mass spectra. Here, we propose a modified MD protocol for simulating discrete Grotthuss diffuse H3O+ that is capable of dynamically altering amino-acid protonation states to model electrospray charging and gaseous ion formation of model proteins, ubiquitin, and myoglobin. Application of the protocol to the evaporation of acidic droplets enables a molecular perspective of H3O+ coordination and proton transfer to/from proteins, which is unfeasible with the metal charge carriers used in previous MD studies of ESI. Our protocol recreates experimentally observed charge-state distributions and supports the charge residue model (CRM) as the dominant mechanism of native protein ionization during ESI. Additionally, our results suggest that protonation is highly specific to individual residues and is correlated to the formation of localized hydrated regions on the protein surface as droplets desolvate. Considering the use of discrete H3O+ instead of Na+, the developed protocol is a necessary step toward developing a more comprehensive model of protein ionization during ESI.


Assuntos
Simulação de Dinâmica Molecular , Prótons , Espectrometria de Massas por Ionização por Electrospray/métodos , Mioglobina/química , Íons/química , Gases/química
14.
Eur J Mass Spectrom (Chichester) ; 30(2): 125-132, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38523368

RESUMO

Lichens are recognized by their unique compounds and diverse applications in food, medicines, and cosmetics. Using ultra-high pressure liquid chromatography, coupled with a high-resolution mass spectrometer, metabolomic profiling of the lichen Parmotrema perlatum, from a methanolic extract, was performed. Based on characteristic fragmentation patterns, twenty-five lichenic substances were tentatively identified including 5 depsides, 12 depsidones, 2 diphenyl ethers, 1 aromatic considered as possible artifact, 1 dibenzofuran, 1 carbohydrate, 1 organic acid, and 2 undefined compounds. To the best of our knowledge, this is a more complete report of their phytochemistry from P perlatum. Our findings of the P perlatum profile may contribute and complement the current data of the Parmotrema genus.


Assuntos
Lactonas , Líquens , Parmeliaceae , Líquens/química , Espectrometria de Massas por Ionização por Electrospray , Chile , Depsídeos , Cromatografia Líquida de Alta Pressão/métodos
15.
Anal Bioanal Chem ; 416(10): 2503-2513, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38523158

RESUMO

Drug screening tests are mandatory in the search for drugs in forensic biological samples, and immunological methods and mass spectrometry (e.g., gas chromatography-mass spectrometry and liquid chromatography-tandem mass spectrometry) are commonly used for that purpose. However, these methods have some drawbacks, and developing new screening methods is required. In this study, we develop a rapid-fire drug screening method by probe electrospray ionization tandem mass spectrometry (PESI-MS/MS), which is an ambient ionization mass spectrometry method, for human urine, named RaDPi-U. RaDPi-U is carried out in three steps: (1) mixing urine with internal standard (IS) solution and ethanol, followed by vortexing; (2) pipetting the mixture onto a sample plate for PESI; and (3) rapid-fire analysis by PESI-MS/MS. RaDPi-U targets 40 forensically important drugs, which include illegal drugs, hypnotics, and psychoactive substances. The analytical results were obtained within 3 min because of the above-mentioned simple workflow of RaDPi-U. The calibration curves of each analyte were constructed using the IS method, and they were quantitatively valid, resulting in good linearity (0.972-0.999) with a satisfactory lower limit of detection and lower limit of quantitation (0.01-7.1 ng/mL and 0.02-21 ng/mL, respectively). Further, both trueness and precisions were 28% or less, demonstrating the high reliability and repeatability of the method. Finally, we applied RaDPi-U to three postmortem urine specimens and successfully detected different drugs in each urine sample. The practicality of the method is proven, and RaDPi-U will be a strong tool as a rapid-fire drug screening method not only in forensic toxicology but also in clinical toxicology.


Assuntos
Espectrometria de Massas por Ionização por Electrospray , Espectrometria de Massas em Tandem , Humanos , Espectrometria de Massas por Ionização por Electrospray/métodos , Espectrometria de Massas em Tandem/métodos , Reprodutibilidade dos Testes , Avaliação Pré-Clínica de Medicamentos , Cromatografia Líquida/métodos
16.
J Chromatogr A ; 1719: 464754, 2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38428340

RESUMO

Aviation turbine fuel is a complex mixture of thousands of compounds. An analytical method using hydrophilic interaction liquid chromatography (HILIC) coupled with electrospray ionization and quadrupole time-of-flight mass spectrometry (ESI-QTOF) was developed for the identification of heteroatomic, polar compounds in aviation turbine fuel. Although compounds containing oxygen, nitrogen, and sulfur functional groups are each found at low levels (<0.1 % by mass) in fuels, their presence can generate significant effects on fuel properties. The HILIC-ESI-QTOF method is a combined separation and detection technique that possesses many advantages including a fast and simple sample preparation-requiring no extraction step therefore ensuring no loss of compounds of interest-and the ability to acquire high-fidelity compound data for chemometric analysis of heteroatomic species in aviation turbine fuel. In the development of the method, it was found that the chromatographic conditions and nature of the injection sample had a significant effect on separation efficiency and repeatability. For a sample dataset optimized using a singular aviation turbine fuel, retention time shift was able to be reduced from 0.4 min to 2.0 % relative standard deviation (RSD) to approximately 0.1 min with RSD of 0.4 % using the newly developed method. In addition, a high number of untargeted molecular features (944) and targeted amines (121) were able to be identified when utilizing optimal method conditions. The specific benefits and limitations of utilizing HILIC techniques with HPLC-ESI-QTOF are also discussed herein. This new method is currently being expanded to include analysis of all heteroatoms and is being applied to real fuel sets. The results of these studies are forthcoming.


Assuntos
Aviação , Espectrometria de Massas por Ionização por Electrospray , Espectrometria de Massas por Ionização por Electrospray/métodos , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia Líquida/métodos , Interações Hidrofóbicas e Hidrofílicas
17.
Metabolomics ; 20(2): 38, 2024 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-38460055

RESUMO

INTRODUCTION: Changes in the categories and concentrations of salivary metabolites may be closely related to oral, intestinal or systemic diseases. To study salivary metabolites, the first analytical step is to extract them from saliva samples as much as possible, while reducing interferences to a minimum. Frequently used extraction methods are protein precipitation (PPT), liquid-liquid extraction (LLE) and solid-phase extraction (SPE), with various organic solvents. The types and quantities of metabolites extracted with different methods may vary greatly, but few studies have systematically evaluated them. OBJECTIVES: This study aimed to select the most suitable methods and solvents for the extraction of saliva according to different analytical targets. METHODS: An untargeted metabolomics approach based on liquid chromatography-mass spectrometry was applied to obtain the raw data. The numbers of metabolites, repeatability of the data and intensities of mass spectrometry signals were used as evaluation criteria. RESULTS: PPT resulted in the highest coverage. Among the PPT solvents, acetonitrile displayed the best repeatability and the highest coverage, while acetone resulted in the best signal intensities for the extracted compounds. LLE with the mixture of chloroform and methanol was the most suitable for the extraction of small hydrophobic compounds. CONCLUSION: PPT with acetonitrile or acetone was recommended for untargeted analysis, while LLE with the mixture of chloroform and methanol was recommended for small hydrophobic compounds.


Assuntos
Metabolômica , Metanol , Solventes/química , Metabolômica/métodos , Metanol/química , Espectrometria de Massas por Ionização por Electrospray/métodos , Clorofórmio , Acetona , Saliva , Acetonitrilas
18.
Int J Mol Sci ; 25(6)2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38542440

RESUMO

Electrospray ionization mass spectrometry (ESI-MS) analysis is frequently associated with noncovalent adduct formation, both in positive and negative modes. Anion binding and sensing by mass spectrometry, notably more challenging compared to cation binding, will have major research potential with the development of appropriate sensors. Here, we demonstrated identification of stable bisquaternary dication adducts with trifluoroacetate (TFA-), Cl- and HSO4- in positive-mode ESI-MS analysis. The observed adducts were stable in MS/MS mode, leading to the formation of characteristic fragment ions containing a covalently bound anion, which requires bond reorganization. This phenomenon was confirmed by computational methods. Furthermore, given that anion detection and anion sensor chemistry have gained significant prominence in chemistry, we conducted an analysis of the fluorescent properties of bisquaternary ammonium compound as a potential anion sensor.


Assuntos
Compostos de Amônio , Espectrometria de Massas por Ionização por Electrospray , Espectrometria de Massas por Ionização por Electrospray/métodos , Espectrometria de Massas em Tandem , Íons , Ânions
19.
Food Chem ; 447: 138928, 2024 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-38484547

RESUMO

In this study, we established a simple, rapid, and high-throughput method for the analysis and classification of propolis samples. We utilized nanoESI-MS to analyze 37 samples of propolis from China for the first time, obtaining characteristic fingerprint spectra in negative ion mode, which were then integrated with multivariate analysis to explore variations between water extract of propolis (WEP) and ethanol extract of propolis (EEP). Furthermore, we categorized propolis samples based on different climate zones and colors, screening 10 differential metabolites among propolis from various climate zones, and 11 differential metabolites among propolis samples of different color. By employing machine learning models, we achieved high-precision discrimination and prediction between samples from different climate zones and colors, achieving predictive accuracies of 95.6% and 85.6%, respectively. These results highlight the significant potential of the nanoESI-MS coupled with machine learning methodology for precise classification within the realm of food products.


Assuntos
Ascomicetos , Própole , Própole/química , Espectrometria de Massas , Clima , Aprendizado de Máquina , Espectrometria de Massas por Ionização por Electrospray/métodos
20.
J Hazard Mater ; 469: 134039, 2024 May 05.
Artigo em Inglês | MEDLINE | ID: mdl-38492401

RESUMO

The transition to mass spectrometry (MS) in the analysis of antibiotics in the marine environment is highly desirable, particularly in the enhancement of sensitivity for high-salinity (3.5 wt%) seawater samples. However, the persistence of complex operational procedures poses substantial challenges to this transition. In this study, a rapid method for the online analysis of antibiotics in seawater samples via nano-electrospray ionization (nESI) MS based on slug-flow microextraction (SFME) has been proposed. Comparisons with other methods, complex laboratory setups for sample processing are now seamlessly integrated into a single online step, completing the entire process, including desalination and detection, SFME-nESI-MS provides faster results in less than 2 min while maintaining sensitivity comparable to that of other detection methods. Using SFME-nESI, six antibiotics in high-salinity (3.5 wt%) seawater samples have been determined in both positive and negative ion modes. The proposed method successfully detected clarithromycin, ofloxacin, and sulfadimidine in seawater within a linear range of 1-1000 ng mL-1 and limit of detection (LOD) of 0.23, 0.06, and 0.28 ng mL-1, respectively. The method recovery was from 92.8% to 107.3%, and the relative standard deviation was less than 7.5%. In addition, the response intensity of SFME-nESI-treated high-salinity (3.5 wt%) samples surpassed that of untreated medium-salinity (0.35 wt%) samples by two to five orders of magnitude. This advancement provides an exceptionally simplified protocol for the online rapid, highly sensitive, and quantitative determination of antibiotics in high-salinity (3.5 wt%) seawater.


Assuntos
Antibacterianos , Espectrometria de Massas por Ionização por Electrospray , Antibacterianos/análise , Espectrometria de Massas por Ionização por Electrospray/métodos , Água do Mar/química , Ofloxacino , Claritromicina
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...